OVERNIGHT DELIVERY24/7 TECH SUPPORT2 YEAR WARRANTY

Search by part number. We have over $7,000,000 of parts, in stock.

- 0 Items
Extend the life of your PLC
Contact Us or Call 1-800-784-9385
The Allen-Bradley / Rockwell Automation 1771-OA 120V AC general-purpose Digital Output Module houses 8 outputs. Operating voltage for 1771OA is 92...138V. Continuous current per output max. is 1.5A and current per module max. is 6A. Backplane current load is 210mA. Wiring arm is the 1771-WA.  
The Allen-Bradley / Rockwell Automation 1771-OAD 120V AC Digital Output Module houses 16 outputs. Operating voltage for 1771OAD is 10...138V. Continuous current per output max. is 2A and current per module max. is 8A. Backplane current load is 295mA. Wiring arm is the 1771-WH. For each output, a blown fuse is reported in the input image table.   
The Allen-Bradley / Rockwell Automation 1771-OAN is a 120/220V AC general-purpose Digital Output Module. This module houses 32 (4 sets pf 8) outputs. Operating voltage for 1771OAN is 80...265V. Current per module max. is 8A. Backplane current load is 800mA. Wiring arm is the 1771-WN.  
Output Module, 10-30 VDC, Source, 8 pt.
The Allen-Bradley / Rockwell Automation 1771-OBD Digital Output Module houses 16 outputs. Operating voltage for 1771OBD is 10...60V. Continuous current per output, max. is 2A and continuous current per module, max. is 8A. Backplane current load is 400mA. Wiring arm is the 1771-WH. 
The Allen-Bradley / Rockwell Automation 1771-OBDS application is electronic fusing/current limiting. Operating voltage for 1771OBDS is 10...40V. This module houses 16 outputs. Continuous current per output max. is 1A and continuous current per module max. is 8A. Backplane current load is 300mA. Wiring arm is the 1771-WH. 
The Allen-Bradley / Rockwell Automation 1771-OBN application is V DC signal termination isolated circuits. Operating voltage for 1771OBN is 10...30V. This module houses 32 (4 sets of 8) outputs. Continuous current per output max. is 0.5A (2A/set) and continuous current per module max. is 8A. Backplane current load is 330mA. Wiring arm is the 1771-WN. 
Output Module, 40-60 VDC, Source, 8 pt.
The Allen-Bradley / Rockwell Automation 1771-OD 120V AC Digital Output Module houses 6 outputs. Its application is isolated circuits; multiple solenoids and transformers. Operating voltage for 1771-OD is 92...138V. Continuous current per output max. is 2A and current per module max. is 6A. Backplane current load is 225mA. Wiring arm is the 1771-WD. 
The Allen-Bradley / Rockwell Automation 1771-OD16 120V AC Digital Output Module houses 16 outputs. Its application is isolated circuits; multiple solenoids and transformers. Operating voltage for 1771-OD16 is 74...138V. Continuous current per output max. is 2A and current per module max. is 8A. Backplane current load is 200mA. Wiring arm is the 1771-WN. 
The Allen-Bradley / Rockwell Automation 1771-ODD 120V AC Digital Output Module houses 16 outputs. Its application is isolated circuits with individual fuse indication; multiple solenoids and transformers. Operating voltage for 1771-ODD is 85...138V. Continuous current per output max. is 2A and current per module max. is 8A. Backplane current load is 420mA. Wiring arm is the 1771-WN. 
The Allen-Bradley / Rockwell Automation 1771-ODZ 120V AC Digital Output Module houses 8 outputs (4 sets of 2). Its application is isolated circuit pairs; replaces 1771-OZ and -OA with resistor, 1771 -IA interlocks. Operating voltage for 1771-ODZ is 92...138V. Continuous current per output max. is 2A and current per module max. is 6A. Backplane current load is 350mA. Wiring arm is the 1771-WD. 
The Allen-Bradley / Rockwell Automation 1771-OG 5 VDC Digital Output Module houses 8 outputs. Its application is TTL interfaces. Operating voltage of 1771OG is 5.0...5.3V (TTL compatible). Continuous current per output max. is 0.02A sink, 0.001A source. Backplane current load is 168mA. Wiring arm is the 1771-WC. 
The Allen-Bradley / Rockwell Automation 1771-OGD 5 VDC Digital Output Module houses 16 outputs. Its application is TTL interfaces. Operating voltage of 1771OGD is 5.0...5.3V (TTL compatible). Continuous current per output max. is 0.20A sink, 0.001A source. Backplane current load is 230mA. Wiring arm is the 1771-WH. 
The Allen-Bradley / Rockwell Automation 1771-OM is a 220V AC general purpose digital output module. 1771-OM houses 8 outputs. Operating voltage of 1771OM is 184...250V. Continuous current per output max. is 2 A and current per module max. is 6A. Backplane current load is 225mA. Wiring arm is the 1771-WA.   
The Allen-Bradley / Rockwell Automation 1771-OMD is a 220V AC general purpose digital output module. 1771-OMD houses 16 outputs. Operating voltage of 1771OMD is 184...250V. Continuous current per output max. is 2 A and current per module max. is 8A. Backplane current load is 700mA. Wiring arm is the 1771-WH.   
The 1771-ON 24V AC digital output module houses 8 outputs. Operating voltage is 20...30V. Applications for 1771ON are relay coil driver and low voltage inductive loads. Continuous current per output max. is 1.5 and current per module max. is 6A. Backplane current load is 225mA. Wiring arm is the 1771-WA. 
The 1771-OP 120V AC digital output module houses 4 outputs. Operating voltage for 1771OP is 92...138V. Each output is protected by opening its fuse if its triAC fails shorted. Continuous current per output max. is 2A and current per module max. is 6A. Backplane current load is 350mA. Wiring arm is the 1771-WA. 
The 1771-OQ application is V DC signal termination isolated circuits. Operating voltage of 1771OQ is 20.4...26.4V. Continuous current per max. is 2.25A and continuous current per module max. is 9A. 1771-OQ houses 8 inputs. Backplane current load is 225mA. Wiring arm is the 1771-WF. 
The 1771-OQ16 are 10...32V DC general purpose (sink or source) isolated circuits that houses 16 outputs. Operating voltage of 1771OQ16 is 10...32V. Continuous current per output max. is 2 A and continuous current per module max. is 32A. Backplane current load is 400mA. Wiring arm is the 1771-WN.