Breuer Motoren
Qualitrol International is proud to provide quality service for Breuer Motoren Ecovert drives and rectifiers. Our technicians have accrued years of hands-on experience with custom in-house testing, equipment, and repair technology to provide prompt and accurate repairs for your crucial Ecovert equipment.
Service for Ecovert drive units includes the disassembling and cleaning of debris and fluid contamination from the unit chassis and PCBs. PCBs are also cleaned in aqueous cleaner and/or ultrasonic and dried in oven, where required. Aluminum electrolytics are replaced on all PCBs. Gate driver PCBs have most major components replaced. Systems test include a burn in running motor under load for a minimum 1 to 3 hours.
Some recently repaired Ecovert models/part numbers include:
- 30KW frequency inverter: ECO80107030410250000
- 80KW frequency inverter: ECO80107030610037270006
- Rectifier unit: ECO80107050710037310002
Specific repairs include:
- Repair and replace damaged semiconductor components
- Repair damaged PCB traces
- Replace IGBT module
- Replace Diode module
- Repair and replace defective DC link components and power stage components
- DC capacitor bank reforming
- Cooling fan rebuild/ replacement
- Rebuild gate driver stage PCBs including transformers, electrolytic capacitors, ICs, and octocouplers
Please use the form below to provide us with some basic information about your business and the specific Breuer Motoren parts to be repaired.